GUY F. ATKINSON CONSTRUCTION, LLC
Requests
Sub-bids from All Qualified & Certified DBE Subcontractors/Suppliers/Consultants
for:
Caltrans Contract 12-0K93U4
Construction on State Highway in Anaheim and Placentia
on Route 57 from Wagner Avenue Overcrossing
to 0.2 Mile North of Miraloma Avenue Overcrossing
and
on Route 91 from 0.1 Mile E of Acacia Street Undercrossing
to 0.2 Mile East of La Palma Ave Overcrossing
in District 12 on Route 57, 91 | 12-Ora-57, 91 – 13.9/16.1, 4.8/6.6
Bids Thursday, July 3, 2025
Scopes of Work: Asphalt, Bridge, Concrete Barrier, Demo, Drainage, Earthwork, Electrical, Erosion Control, Fencing, Flatwork, JCPC Rapid Set, Landscaping, MBGR, Maintenance of Traffic, Pavement Marking, Paving, QA/QC / Testing, Rebar, Signs, Street Sweeping, Survey, Trucking, Utilities, Water Trucks.
Services Needed Include (but are not limited to): LEAD COMPLIANCE PLAN, LEVEL 2 CRITICAL PATH METHOD SCHEDULE, DISPUTE RESOLUTION BOARD ON-SITE MEETING, HOURLY OFF-SITE DISPUTE- RESOLUTION-BOARD- RELATED TASKS, SAFETY QUALITY CONTROL MANAGER, CONSTRUCTION AREA SIGNS, TRAFFIC CONTROL SYSTEM, TRAFFIC CONTROL SUPERVISOR, STATIONARY IMPACT ATTENUATOR VEHICLE, AUTOMATED WORK ZONE INFORMATION SYSTEM, FLASHING ARROW SIGN, TYPE II BARRICADE, TYPE Ill BARRICADE, TEMPORARY PAVEMENT MARKING (PAINT), TEMPORARY TRAFFIC STRIPE (PAINT), CHANNELIZER (SURFACE MOUNTED), TRAFFIC DRUM, PORTABLE RADAR SPEED FEEDBACK SIGN SYSTEM, TEMPORARY BARRIER SYSTEM, TEMPORARY PEDESTRIAN ACCESS ROUTE, PORTABLE CHANGEABLE MESSAGE SIGN (EA), TEMPORARY RAILING (TYPE K), TEMPORARY CRASH CUSHION MODULE, TEMPORARY CRASH CUSHION TL-2, TEMPORARY CRASH CUSHION TL-3, TEMPORARY TRAFFIC SCREEN, TEMPORARY RADAR SPEED FEEDBACK SIGN SYSTEM, JOB SITE MANAGEMENT, STORMWATER POLLUTION PREVENTION PLAN, STORMWATER SAMPLING AND ANALYSIS DAY, STORM WATER ANNUAL REPORT, TEMPORARY COVER, TEMPORARY CHECK DAM, TEMPORARY DRAINAGE INLET PROTECTION, TEMPORARY FIBER ROLL, TEMPORARY CONSTRUCTION ENTRANCE, STREET SWEEPING, TEMPORARY CONCRETE WASHOUT, ASBESTOS COMPLIANCE PLAN, WORK AREA MONITORING (BRIDGE), TREATED WOOD WASTE, INVASIVE SPECIES CONTROL, VIBRATION MONITORING, PHOTO AND VIDEO SURVEY OF EXISTING NON-HIGHWAY FACILITIES, REMOVE CONCRETE (MISCELLANEOUS) (SQFT), REMOVE CONCRETE (ANCHOR BLOCK), CLEARING AND GRUBBING (LS), REMOVE TREE, ROADWAY EXCAVATION, (F) - STRUCTURE EXCAVATION (BRIDGE), (F) - STRUCTURE EXCAVATION (RETAINING WALL), (F) - STRUCTURE EXCAVATION (SOUND WALL), STRUCTURE EXCAVATION (SOLDIER PILE WALL), STRUCTURE EXCAVATION (GROUND ANCHOR WALL), (F) - STRUCTURE BACKFILL (BRIDGE), (F) - STRUCTURE BACKFILL (SLURRY CEMENT), (F) - STRUCTURE BACKFILL (RETAINING WALL), (F) - STRUCTURE BACKFILL (SOUND WALL), STRUCTURE BACKFILL (GROUND ANCHOR WALL), STRUCTURE BACKFILL (SOLDIER PILE WALL), (F) - PERVIOUS BACKFILL MATERIAL (RETAINING WALL), CONCRETE BACKFILL (SOLDIER PILE WALL), LEAN CONCRETE BACKFILL, DITCH EXCAVATION, IMPORTED BORROW (CY), SUBGRADE ENHANCEMENT GEOTEXTILE, CLASS A2, ROADSIDE CLEARING, ROCK BLANKET, WEED GERMINATION, CULTIVATION, IRON SULFATE (LB), SOIL AMENDMENT, RELOCATE BACKFLOW PREVENTER ASSEMBLY, RELOCATE WATER METER, PACKET FERTILIZER, SLOW-RELEASE FERTILIZER, SOIL TESTING, PLANT (GROUP F), PLANT (GROUP K), PLANT (GROUP A), PLANT (GROUP B), PLANT (GROUP U), SOD, PLANT ESTABLISHMENT WORK, WOOD MULCH, ROOT BARRIER, CHECK AND TEST EXISTING IRRIGATION FACILITIES, OPERATE EXISTING IRRIGATION FACILITIES, REMOVE IRRIGATION FACILITY, CONTROL AND NEUTRAL CONDUCTORS (ARMOR- CLAD), CONTROL AND NEUTRAL CONDUCTORS, l" REMOTE CONTROL VALVE, 11/2" REMOTE CONTROL VALVE, 2" REMOTE CONTROL VALVE, 16-18 STATION IRRIGATION CONTROLLER(PEDESTAL MOUNTED), TWO-WIRE IRRIGATION CONTROLLER, REMOTE CONTROL VALVE DECODER, FLOW SENSOR DECODER, MASTER VALVE DECODER, IRRIGATION CONTROLLER ENCLOSURE CABINET, FLOW SENSOR, TREE WELL SPRINKLER ASSEMBLY, RISER SPRINKLER ASSEMBLY (GEAR DRIVEN), POP-UP SPRINKLER ASSEMBLY (GEAR DRIVEN), RISER SPRINKLER ASSEMBLY, POP-UP SPRINKLER ASSEMBLY, 2" GATE VALVE, 2 1/2"GATE VALVE, 3" GATE VALVE, (F) -1" PLASTIC PIPE (SCHEDULE 40)(SUPPLY LINE), (F)-11/4"PLASTIC PIPE (SCHEDULE 40)(SUPPLY LINE), (F) -11/2"PLASTIC PIPE (SCHEDULE 40)(SUPPLY LINE), (F) - 2" PLASTIC PIPE (SCHEDULE 40)(SUPPLY LINE), (F) - 21/2"PLASTIC PIPE (SCHEDULE 40)(SUPPLY LINE), (F) - 2" PLASTIC PIPE (CLASS 315)(SUPPLYLINE), (F) - 21/2"PLASTIC PIPE (CLASS 315)(SUPPLY LINE), (F) - 3" PLASTIC PIPE (CLASS 315)(SUPPLYLINE), CHECK VALVE, BALL VALVE, 2 1/2"BALL VALVE, (F) - PVC PIPE CONDUIT (SLEEVE), 12" CORRUGATED HIGH DENSITY POLYETHYLENE PIPE CONDUIT, 6" CORRUGATED STEEL PIPE CONDUIT (.064"THICK), CLASS 2 AGGREGATE SUBBASE, CLASS 3 AGGREGATE SUBBASE, CLASS 2 AGGREGATE BASE (CY), LEAN CONCRETE BASE, LEAN CONCRETE BASE RAPID SETTING, CEMENT TREATED PERMEABLE BASE, BASE BOND BREAKER, CRACK TREATMENT, PRIME COAT, HOT MIX ASPHALT (TYPE A), RUBBERIZED HOT MIX ASPHALT (GAP GRADED), PLACE HOT MIX ASPHALT DIKE (TYPE C), PLACE HOT MIX ASPHALT DIKE (TYPED), PLACE HOT MIX ASPHALT DIKE (TYPE E), PLACE HOT MIX ASPHALT DIKE (TYPE F), TACK COAT, REMOVE ASPHALT CONCRETE PAVEMENT (CY), REMOVE ASPHALT CONCRETE DIKE, COLD PLANE ASPHALT CONCRETE PAVEMENT, REMOVE BASE AND SURFACING, JOINTED PLAIN CONCRETE PAVEMENT, JOINTED PLAIN CONCRETE PAVEMENT (RSC), DRILL AND BOND (DOWEL BAR), DRILL AND BOND (TIE BAR), SPALL REPAIR (FAST- SETTING CONCRETE), ISOLATION JOINT SEAL (SILICONE), REMOVE CONCRETE PAVEMENT (CY), GRIND EXISTING CONCRETE PAVEMENT, GROUND ANCHOR (SUBHORIZONTAL), STEEL SOLDIER PILE (HP 12 X89), STEEL SOLDIER PILE (HP 16 X 121), STEEL SOLDIER PILE (HP 18 X 181), STEEL SOLDIER PILE (2- HP 12 X 53), 36" DRILLED HOLE, 42" DRILLED HOLE, 102" PERMANENT STEEL CASING, 16" CAST-IN-DRILLED-HOLE CONCRETE PILING, 24" CAST-IN-DRILLED-HOLE CONCRETE PILING, 48" CAST-IN-DRILLED-HOLE CONCRETE PILING, 54" CAST-IN-DRILLED-HOLE CONCRETE PILING, 60" CAST-IN-DRILLED-HOLE CONCRETE PILING, 72" CAST-IN-DRILLED-HOLE CONCRETE PILING, 90" CAST-IN-DRILLED-HOLE CONCRETE PILING, 102" CAST-IN-DRILLED- HOLE CONCRETE PILING, FURNISH PILING (CLASS 200, ALTERNATIVE X), DRIVE PILE (CLASS 200, ALTERNATIVE X), 16" CAST-IN-DRILLED-HOLE CONCRETE PILING (SOUND WALL), 60" CAST-IN-DRILLED-HOLE CONCRETE PILE (SIGN FOUNDATION), 72" CAST-IN-DRILLED-HOLE CONCRETE PILE (SIGN FOUNDATION), 78" CAST-IN-DRILLED-HOLE CONCRETE PILE (SIGN FOUNDATION), PRESTRESSING PRECAST GIRDER, (F) - STRUCTURAL CONCRETE, BRIDGE FOOTING, (F) - STRUCTURAL CONCRETE, BRIDGE, (F) - STRUCTURAL CONCRETE, BRIDGE (POLYMER FIBER), (F) - STRUCTURAL CONCRETE, RETAINING WALL, (F) - STRUCTURAL CONCRETE, SOUND WALL, (F) - STRUCTURAL CONCRETE, WALL FACING, (F) - STRUCTURAL CONCRETE, BARRIER SLAB, (F) - STRUCTURAL CONCRETE, APPROACH SLAB (TYPE N), STRUCTURAL CONCRETE, APPROACH SLAB (TYPE R), (F) - STRUCTURAL CONCRETE, HEADWALL, (F) - STRUCTURAL CONCRETE, DRAINAGE INLET, MINOR CONCRETE; (F) - MINOR CONCRETE (MINOR STRUCTURE), (F) - MINOR CONCRETE (BACKFILL), CONCRETE SURFACE TEXTURE (FRACTURED RIB), DRILL AND BOND DOWEL, DRILL AND BOND DOWEL (CHEMICAL ADHESIVE)(LF), CLEAN EXPANSION JOINT, FURNISH PRECAST PRESTRESSED CONCRETE GIRDER (60'-70'), FURNISH PRECAST PRESTRESSED CONCRETE GIRDER (70'-80'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (70'-80'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (60'-70'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (140'-150'), FURNISH PRECAST PRESTRESSED CONCRETE TRAPZOIDAL GIRDER (70'-80'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (30'-40'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (40'-50'), FURNISH PRECAST PRESTRESSED CONCRETE WIDE FLANGE GIRDER (110'-120'), ERECT PRECAST PRESTRESSED CONCRETE GIRDER, PIPE PIN, JOINT SEAL (MR 1/2"), JOINT SEAL (MR l"), STRIP JOINT SEAL ASSEMBLY (MR 21/2"), (F) - BAR REINFORCING STEEL (WALL FACING), (F) - BAR REINFORCING STEEL (BRIDGE), (F) - BAR REINFORCING STEEL (RETAINING WALL), (F) - BAR REINFORCING STEEL (SOUND WALL), (F) - HEADED BAR REINFORCEMENT, (F) - STRUCTURAL SHOTCRETE, (F) - FURNISH SIGN STRUCTURE (BRIDGE MOUNTED WITHOUT WALKWAY), (F) - INSTALL SIGN STRUCTURE (BRIDGE MOUNTED WITHOUT WALKWAY), FURNISH SIGN STRUCTURE (VERSATILE TRUSS), INSTALL SIGN STRUCTURE (VERSATILE TRUSS), REMOVE SIGN STRUCTURE (EA), REMOVE BRIDGE MOUNTED SIGN, TIMBER LAGGING, (F) - SOUND WALL (MASONRY BLOCK), CLEAN AND PAINT STEEL SOLDIER PILING, REMOVE RETAINING WALL (LF), REMOVE RETAINING WALL (PORTION) (CY), REFINISH BRIDGE DECK, REMOVE SOUND WALL (LF), BRIDGE REMOVAL, BRIDGE REMOVAL (PORTION), LOCATION A, BRIDGE REMOVAL (PORTION), LOCATION B, BRIDGE MONITORING, DPP INFILTRATION AREA (ROCK INFILL), TRASH NET (END OF PIPE CONNECTION), CAPTURE HOUSING TYPE B (3<D=4), CAPTURE HOUSING (TYPE A) (4<D=4), 18" SLOTTED PLASTIC PIPE, 18" REINFORCED CONCRETE PIPE, 24" REINFORCED CONCRETE PIPE,30" REINFORCED CONCRETE PIPE, 48" REINFORCED CONCRETE PIPE (CLASS V) (LF), 8" CORRUGATED STEEL PIPE (.064" THICK), 18" CORRUGATED STEEL, PIPE (.109" THICK), 24" CORRUGATED STEEL, PIPE (.109" THICK), 36" CORRUGATED STEEL PIPE (.109" THICK), 12" SLOTTED PLASTIC PIPE (LF), 3" PLASTIC PIPE (EDGE DRAIN), 3" PLASTIC PIPE (EDGE DRAIN OUTLET), ANCHOR ASSEMBLY, 18" CORRUGATED STEEL PIPE RISER (.109" THICK), 14" WELDED STEEL PIPE CASING (BRIDGE), 20" WELDED STEEL PIPE CASING (BRIDGE), 18" CONCRETE FLARED END SECTION, 48" CONCRETE FLARED END SECTION, 36" PRECAST CONCRETE PIPE MANHOLE, ABANDON CULVERT (LF), ABANDON INLET, REMOVE OVERSIDE DRAIN, REMOVE CULVERT (LF), REMOVE DOWNDRAIN (EA), REMOVE REINFORCED CONCRETE BOX CULVERT (LF), REMOVE INLET, REMOVE HEADWALL, REMOVE EDGE DRAIN, REMOVE FLARED END SECTION (EA), ADJUST INLET, ADJUST FRAME AND COVER TO GRADE, ABANDON EDGE DRAIN, REMOVE CONCRETE (CHANNEL), CAP INLET, CLEANING, INSPECTING, AND PREPARING CULVERT (LF), SAND BACKFILL, 24" CURED-IN-PLACE PIPELINER, REMOVE SLOPE PAVING (SQYD), CONCRETE (DITCH LINING), CONCRETE (CHANNEL LINING), CONCRETE(CONCRETE APRON), SLOPE PAVING (CONCRETE), ROCK SLOPE PROTECTION (300 LB, CLASS IV, METHOD B) (CY), ROCK SLOPE PROTECTION (60 LB, CLASS II, METHOD B) (CY), ROCK SLOPE PROTECTION (20 LB, CLASS I, METHOD B) (CY), ROCK SLOPE PROTECTION FABRIC (CLASS 8), FILTER FABRIC, MINOR CONCRETE (GUTTER) (LF), DETECTABLE WARNING SURFACE, MINOR CONCRETE (CURB AND GUTTER), MINOR CONCRETE (GUTTER DEPRESSION), MINOR CONCRETE (EXPOSED AGGREGATE CONCRETE), MINOR CONCRETE (SIDEWALK), MINOR CONCRETE (TEXTURED PAVING), MINOR CONCRETE (CURB RAMP), REMOVE CONCRETE SIDEWALK (SQYD), REMOVE CONCRETE (CURB AND GUTTER), BOOSTER PUMP, (F) - MISCELLANEOUS IRON AND STEEL, ISOLATION CASING (CORRUGATED STEEL PIPE), (F) - MISCELLANEOUS METAL (BRIDGE), (F) - MISCELLANEOUS METAL (RETAINING WALL), MODIFYING SIGNAL AND LIGHTING (CITY), LIGHTING SYSTEM (CITY), TEMPORARY FIBER OPTIC CABLE SYSTEMS (CITY), FIBER OPTIC CABLE SYSTEMS (CITY), PAINT CURB (2-COAT), TEMPORARY FENCE (SLATTED), CHAIN LINK FENCE (TYPE CL-6), 4' CHAIN LINK GATE (TYPE CL-6), 12' CHAIN LINK GATE (TYPE CL-6), REMOVE CHAIN LINK FENCE, REMOVE PAVEMENT MARKER, DELINEATOR (SPECIAL), DELINEATOR (CLASS 1), GUARD RAILING DELINEATOR, PAVEMENT MARKER (NON- REFLECTIVE), PAVEMENT MARKER (RETROREFLECTIVE), TREATMENT BEST MANAGEMENT PRACTICE MARKER, REMOVE ROADSIDE SIGN, REMOVE ROADSIDE SIGN (METAL POST), REMOVE ROADSIDE SIGN (STRAP AND SADDLE BRACKET METHOD), REMOVE ROADSIDE SIGN PANEL, REMOVE SIGN FROM SIGN FRAME, REMOVE SIGN PANEL, REMOVE SIGN OVERLAY, RESET ROADSIDE SIGN, RELOCATE ROADSIDE SIGN, FURNISH FORMED PANEL SIGN (OVERHEAD), FURNISH LAMINATED PANEL SIGN (l"-TYPE A), FURNISH LAMINATED PANEL SIGN (l"-TYPE B), FURNISH SINGLE SHEET ALUMINUM SIGN (0.063"- UNFRAMED), FURNISH SINGLE SHEET ALUMINUM SIGN (0.080"- UNFRAMED), FURNISH SINGLE SHEET ALUMINUM SIGN (0.063"- FRAMED), FURNISH SINGLE SHEET ALUMINUM SIGN (0.080"- FRAMED), METAL (BARRIER MOUNTED SIGN), ROADSIDE SIGN - ONE POST, ROADSIDE SIGN - TWO POST, INSTALL SIGN (STRAP AND SADDLE BRACKET METHOD), INSTALL SIGN OVERLAY, INSTALL SIGN (MAST-ARM HANGER METHOD), INSTALL SIGN PANEL ON EXISTING FRAME, INSTALL ROADSIDE SIGN PANEL ON EXISTING POST, INSTALL ROADSIDE SIGN (LAMINATED WOOD BOX POST), INSTALL ROADSIDE SIGN IN CONCRETE, MIDWEST GUARDRAIL SYSTEM (WOOD POST), PICKET RAILING, (F) - CHAIN LINK RAILING (TYPE 7 MODIFIED), (F) - TUBULAR HANDRAILING, (F) - CABLE RAILING, TRANSITION RAILING (TYPE AGT), END CAP (TYPE A), END CAP (TYPE TC), END ANCHOR ASSEMBLY (TYPE SFT-M), ALTERNATIVE CRASH CUSHION TL-2, ALTERNATIVE IN-LINE TERMINAL TL-3, ALTERNATIVE CRASH CUSHION TL-3, CONCRETE BARRIER (TYPE 60M), CONCRETE BARRIER (TYPE 60MC), CONCRETE BARRIER (TYPE 60MD), CONCRETE BARRIER (TYPE 60MG), CONCRETE BARRIER (TYPE 60MGF), CONCRETE BARRIER (TYPE 60MS), CONCRETE BARRIER (TYPE 60MSC), CONCRETE BARRIER (TYPE 60MSF), (F) - CONCRETE BARRIER (TYPE 732SW), (F) - CONCRETE BARRIER (TYPE 732SW MODIFIED), (F) - CONCRETE BARRIER (TYPE 836 MODIFIED), (F) - CONCRETE BARRIER (TYPE 836B), (F) - CONCRETE BARRIER TRANSITION, (F) - CONCRETE BARRIER (TYPE 842), (F) - CONCRETE BARRIER (TYPE 842A), (F) - CONCRETE BARRIER (TYPE 842B), REMOVE GUARDRAIL, REMOVE CABLE RAILING, REMOVE CONCRETE BARRIER, REMOVE CRASH CUSHION, 3" THERMOPLASTIC TRAFFIC STRIPE (SOLID BLACK) THERMOPLASTIC PAVEMENT MARKING (ENHANCED WET NIGHT VISIBILITY), 4" THERMOPLASTIC TRAFFIC STRIPE (ENCHANCED WET NIGHT VISIBILITY) (BROKEN 16-8), 6" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY) (BROKEN 6-1), 4" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY) (BROKEN 36-12), PAINT TRAFFIC STRIPE (2- COAT), 4" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY), 6" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY), 6" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY) (BROKEN 8-4), 8" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY), 8" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY) (BROKEN 12-3), 12" THERMOPLASTIC TRAFFIC STRIPE (ENHANCED WET NIGHT VISIBILITY), REMOVE PAINTED TRAFFIC STRIPE, REMOVE PAINTED PAVEMENT MARKING, REMOVE THERMOPLASTIC TRAFFIC STRIPE, 6" RUMBLE STRIP (ASPHALT CONCRETE PAVEMENT), 12" RUMBLE STRIP (ASPHALT CONCRETE PAVEMENT), 12" RUMBLE STRIP (CONCRETE PAVEMENT), CONTRAST STRIPE THERMOPLASTIC, 6" TRAFFIC STRIPE TAPE (WARRANTY) (BROKEN 17-7), 6" TRAFFIC STRIPE TAPE (WARRANTY) (BROKEN 36-12), 8" TRAFFIC STRIPE TAPE (WARRANTY) (BROKEN 36-12), 6" TRAFFIC STRIPE TAPE WITH CONTRAST (WARRANTY) (BROKEN 17-7), 6" TRAFFIC STRIPE TAPE WITH CONTRAST (WARRANTY) (BROKEN 36-12), 8" TRAFFIC STRIPE TAPE WITH CONTRAST (WARRANTY) (BROKEN 36-12), TRAFFIC CENSUS STATION SYSTEMS, MODIFYING FIBER OPTIC CABLE SYSTEMS, MODIFYING FIBER OPTIC CABLE SYSTEMS (SHOPP), TEMPORARY LIGHTING SYSTEMS, TEMPORARY CAMERA SYSTEMS, TEMPORARY RAMP METERING SYSTEMS, TEMPORARY FIBER OPTIC CABLE SYSTEMS, MODIFYING CAMERA SYSTEMS, MODIFYING CAMERA SYSTEMS (SHOPP), MODIFYING LIGHTING SYSTEMS, MODIFYING RAMP METERING SYSTEMS, MODIFYING RAMP METERING SYSTEMS (SHOPP), REMOVING LIGHTING SYSTEMS, REMOVING TRAFFIC MONITORING STATIONS, MODIFYING LIGHTING SYSTEMS (SHOPP), QA/QC / TESTING, TRUCKING, SUPER 10s, END DUMPS, DOUBLE BOTTOMS, SURVEY.
REFER TO PROJECT SPECS AND ANY ADDENDA FOR COMPLETE BID ITEM LIST
ENGINEER’S ESTIMATE is $140,000,000
22% DBE Project Goal
*****Lower Tier DBE participation is greatly encouraged*****
Guy F. Atkinson Construction, LLC
611 Anton Blvd, Suite 1100, Costa Mesa, CA 92626
Contractor’s License # 1004388
socal.estimating@atkn.com
Phone: 949-382-7145 / Fax: 949-769-5600
Guy F. Atkinson Construction, LLC is a union contractor and an Equal Opportunity Employer. Atkinson is signatory to the Carpenters, Cement Masons, Laborers and Operating Engineers Unions. 100% Performance & Payment Bonds from an approved surety company will be required for subcontractors with contract value greater than $100,000. Atkinson will pay the cost of bonds. Atkinson will assist in obtaining necessary equipment, supplies, materials or related assistance or services. We will split items of work (see project specs for full list of bid items) and provide assistance for bonding, LOC and insurance where needed. Subcontractors will be expected to sign Atkinson's standard subcontract and to comply with our company's standard insurance requirements which include a waiver of subrogation. Please provide contractor's license number, Department of Industrial Relations (DIR) registration number and DBE cert # (if applicable) with your quote.
Atkinson requests that subs and vendors register in Building Connected and subs prequalify or update in TradeTapp, our online platform prior to bidding.
TO DOWNLOAD PLANS, SPECS, THE INFO HANDOUT, ETC and VIEW Q&A: Please go to the Caltrans Contracts web site: https://ppmoe.dot.ca.gov/des/oe/weekly-ads/oe-project-calendar.php?q=12-0K93U4
OR CONTACT ATKINSON to access all bid documents through our online platform, BuildingConnected.
Please contact Atkinson with any questions or for help with your bid. |