www.Contractors Estimate.com
Certified DGS Trade and Focus Publication since 2002


CE Trade - Trade Paper
 
Online DVBE certification is here!
ARTICLES
&
EDITORIALS

RESOURCES
&
LINKS

City of San Diego SLBE - ELBE Program

SBE/DVBE Search

Minority Business Development Agency

Advertisement date: January 6, 2021 @ 1:00 p.m. through bid opening date

License# 681827

Comet Electric, Inc an Equal Opportunity Employer is requesting sub-bids from all qualified subcontractors and suppliers including certified CBE firms performing commercially useful function for referenced project:

Project Name: On‐Call Traffic Signal Construction, Fiscal Year 2020‐21
Agency: Public Works Los Angeles County
PROJECT NO. TDS0001753
Bid Date: February 2, 2021 at 11:00 A.M.

BRIEF DESCRIPTION: The Work generally consists of the construction or modification of traffic signals, pedestrian flashers, in‐roadway warning light systems and street light conduit on an on‐call basis at various locations throughout the Los Angeles County basin, and Santa Clarita areas.

Plans and Specs can be viewed for free at our office or at:
https://dpw.lacounty.gov/contracts/Opportunities.aspx

CBE Goal: 25%

Quotes for Services and Supplies requested for the following items for bid including, but not limited to: Allowance For Payment & Performance Bonds (Allowance Of $16,000), City Permit And Inspection Fees (Allowance Of $5,000), Sce Service Fee (Allowance Of $12,000), Roadway Work (Allowance Of $50,000), Exploratory Excavation Of Utilities (Allowance Of $120,000), Concrete Removal (Non‐Reinforced), Unclassified Excavation, Crushed Miscellaneous Base, Trench Backfill Slurry (Class 270‐E‐500), Pcc Curb & Gutter, Type A2‐Var, Pcc Walk, Drives, And Curb Ramps, 4" Thick, Ac Pavement (Patch Back), Detectable Warning Surface, 1" Conduit (Sch 80 Pvc), 1" Conduit (Grc), 1‐1/2" Conduit (Sch 80 Pvc), 1‐1/2" Conduit (Grc), 2" Conduit (Sch 80 Pvc), 2" Conduit (Grc), 3" Conduit (Sch 80 Pvc), 3" Conduit (Grc), 1‐Pair Detector Lead‐In Cable, 2‐Pair Detector Lead‐In Cable, 3‐Conductor Signal Cable (Excluding Conduit), 5‐Conductor Signal Cable (Excluding Conduit), 8‐Conductor Signal Cable (Excluding Conduit), 12‐Conductor Signal Cable (Excluding Conduit), 28‐Conductor Signal Cable (Excluding Conduit), Wire #6, Wire #8, Wire #10, Wire #12, No. 5 Pull Box Incl Pcc Cover, No. 5 (T) Pull Box Incl Steel Cover, No. 6 Pull Box Incl Pcc Cover, No. 6 (T) Pull Box Incl Steel Cover, Composite Type 2 Pull Box Incl Cover, Composite Type 3 Pull Box Incl Cover, Inductive Loop Detector And Leads Saw Cut, Furnish 1‐Camera Video Detection System, Furnish 2‐Camera Video Detection System, Furnish 3‐Camera Video Detection System, Furnish 4‐Camera Video Detection System, Furnish 4‐Camera Video/Radar Detection System, Install 1‐Camera Video Detection System, Install 2‐Camera Video Detection System, Install 3‐Camera Video Detection System, Install 4‐Camera Video Detection System, 4‐Camera Video/Radar Detection System, Rack Mount 17" Lcd Monitor, Reinstall Video Detection System ‐ 1 Camera, Reconfig Video Detection Zone ‐ 1 Camera, Remove Ppb Post And Resurface Sidewalk, Remove Ppb Post Complete, Remove Type 1 Standard (Complete) (Excl. Found.), Remove Type 15Ts Standard (Complete) (Excl. Found.), Remove Type 16 Standard (Complete) (Excl. Found.), Remove Type 17 Standard (Complete) (Excl. Found.), Remove Type 18 Standard (Complete) (Excl. Found.), Remove Type 19 Standard (Complete) (Excl. Found.), Remove Type 23 Standard (Complete) (Excl. Found.), Remove Type 24 Standard (Complete) (Excl. Found.), Remove Type 26 Standard (Complete) (Excl. Found.), Remove Type 27 Standard (Complete) (Excl. Found.), Remove Type 28 Standard (Complete) (Excl. Found.), Remove Type 29 Standard (Complete) (Excl. Found.), Remove Type 60 Standard (Complete) (Excl. Found.), Remove Type 61 Standard (Complete) (Excl. Found.), Temporary Type 1 Standard, Temporary Type 15Ts Standard, Temporary Type 16 Standard, Temporary Type 17 Standard, Remove Signal 15' Mast Arm, Remove Signal 20' Mast Arm, Remove Signal 30' Mast Arm, Remove Signal 35' Mast Arm, Remove Signal, 40' Mast Arm, Remove 8' Luminaire Mast Arm, Remove 12' Luminaire Mast Arm, Remove Luminaire, Remove Vehicle Head (Complete), Remove Pedestrian Head (Complete), Remove Pedestrian Push Button, Remove Illuminated Street Name Sign, Remove Controller Cabinet Foundation, Remove Controller Cabinet Complete, Remove Service Cabinet Foundation, Remove Service Cabinet (Complete), Remove Electrical Service, Remove Ppb Post Foundation, Remove Type 1 Foundation, Remove Type 15Ts Foundation, Remove Type 16 Foundation, Remove Type 17 Foundation, Remove Type 18 Foundation, Remove Type 19 Foundation, Remove Type 23 Foundation, Remove Type 24 Foundation, Remove Type 26 Foundation, Remove Type 27 Foundation, Remove Type 28 Foundation, Remove Type 29 Foundation, Remove Type 60 Foundation, Remove Type 61 Foundation, Remove 1‐Camera Video Detection System (Complete), Relocate Type 332 Cabinet (Complete), Relocate Vehicle Head (Complete), Relocate Pedestrian Head (Complete), Relocate Pedestrian Push Button, Relocate Retroreflective Street Name Sign, Temporary Controller, Furnish Type 170 Controller ‐ Atc‐ Hc11, Install Type 170 Atc/Hc‐11 Contoller, Furnish Type 2070 Controller (La City Spec), Install Type 2070 Controller, Gps Utb Unit And Antenna, Switch Pack, Ped Isolation Module, 2‐Channel Ild Sensor Unit, 4‐Channel Ild Sensor Unit, Furnish Type 332 Cabinet, Install Type 332 Cabinet, Type 332 Cabinet Foundation, Furnish Type Iii‐Bf Service Cabinet, Furnish Type Iii‐Bf Service Cabinet W/Bbs, Install Type Iii ‐ Service Cabinet, Install Type Iii‐Bf Service Cabinet W/Bbs, Type Iii‐Bf Service Cabinet Foundation, Type Iii‐Bf Service Cabinet With Bbs Foundation, Modify Type Iii‐Bf Service For Battery Back Up, Relocate Type Iii‐Bf Service, Furnish Pedestrian Push Button Post W/ Anchor Bolts, Furnish Type 15Ts Standard W/ Anchor Bolts, Furnish Type 15Ts Standard W/ Anchor Bolts (Modified To Height Of 20 Feet), Furnish Type 16 Standard W/ Anchor Bolts, Furnish Type 17 Standard W/ Anchor Bolts, Furnish Type 18 Standard W/ Anchor Bolts, Furnish Type 19 Standard W/ Anchor Bolts, Furnish Type 23 Standard W/ Anchor Bolts, Furnish Type 24 Standard W/ Anchor Bolts, Furnish Type 26 Standard W/ Anchor Bolts, Furnish Type 27 Standard W/ Anchor Bolts, Furnish Type 28 Standard W/ Anchor Bolts, Furnish Type 29 Standard W/ Anchor Bolts, Furnish Type 60 Standard W/ Anchor Bolts, Furnish Type 61 Standard W/ Anchor Bolts, Install Pedestrian Push Button Post, Install Type 15Ts Standard, Install Type 16 Standard, Install Type 17 Standard, Install Type 18 Standard, Install Type 19 Standard, Install Type 23 Standard, Install Type 24 Standard, Install Type 26 Standard, Install Type 27 Standard, Install Type 28 Standard, Install Type 29 Standard, Install Type 60 Standard, Install Type 61 Standard, Pedestrian Push Button Post Foundation, Type 15Ts Standard Foundation, Type 16 Standard Foundation, Type 17 Standard Foundation, Type 18 Standard Foundation, Type 19 Standard Foundation, Type 23 Standard Foundation, Type 24 Standard Foundation, Type 26 Standard Foundation, Type 27 Standard Foundation, Type 28 Standard Foundation, Type 29 Standard Foundation, Type 60 Standard Foundation, Type 61 Standard Foundation, Furnish 15' Signal Mast Arm With Mounting Bolts, Furnish 20' Signal Mast Arm With Mounting Bolts, Furnish 25' Signal Mast Arm With Mounting Bolts, Furnish 30' Signal Mast Arm With Mounting Bolts, Furnish 35' Signal Mast Arm With Mounting Bolts, Furnish 40' Signal Mast Arm With Mounting Bolts, Furnish 45' Signal Mast Arm With Mounting Bolts, Furnish 50' Signal Mast Arm With Mounting Bolts, Furnish 55' Signal Mast Arm With Mounting Bolts, Furnish 60' Signal Mast Arm With Mounting Bolts, Furnish 65' Signal Mast Arm With Mounting Bolts, Install 15' Signal Mast Arm, Install 20' Signal Mast Arm, Install 25' Signal Mast Arm, Install 30' Signal Mast Arm, Install 35' Signal Mast Arm, Install 40' Signal Mast Arm, Install 45' Signal Mast Arm, Install 50' Signal Mast Arm, Install 55' Signal Mast Arm, Install 60' Signal Mast Arm, Install 65' Signal Mast Arm, Furnish 6' Luminaire Mast Arm With Mounting Bolts, Furnish 6' Straight Luminaire Mast Arm With Mounting Bolts, Furnish 8' Luminaire Mast Arm With Mounting Bolts, Furnish 8' Straight Luminaire Mast Arm With Mounting Bolts, Furnish 12' Luminaire Mast Arm With Mounting Bolts, Furnish 12' Straight Luminaire Mast Arm With Mounting Bolts, Furnish 15' Luminaire Mast Arm With Mounting Bolts, Furnish 15' Straight Luminaire Mast Arm With Mounting Bolts, Install 6' Luminaire Mast Arm, Install 8' Luminaire Mast Arm, Install 12' Luminaire Mast Arm, Install 15' Luminaire Mast Arm, Furnish Led Luminaires (100W Hps Equivalent), Furnish Led Luminaires (150W Hps Equivalent), Furnish Led Luminaires (200W Hps Equivalent), Furnish Led Luminaires (250W Hps Equivalent), Install Led Luminaires (100W Hps Equivalent), Install Led Luminaires (150W Hps Equivalent), Install Led Luminaires (200W Hps Equivalent), Install Led Luminaires (250W Hps Equivalent), Furnish Pedestrian Push Button, Furnish Pedestrian Push Button Plate, Install Pedestrian Push Button, Install Pedestrian Push Button Plate, Furnish Aps Ppb With Special Voice Message, Install Aps Ppb With Special Voice Message, Furnish Central Controller Unit Aps, Install Central Controller Unit Aps, Furnish Retroreflective Street Name Sign, Install Retroreflective Street Name Sign, Furnish 8' Straight Arm Clamp‐On For Street Name Sign, Install 8' Straight Arm Clamp‐On For Street Name Sign, Furnish 1‐12" Led Yellow Flasher, Install 1‐12" Led Yellow Flasher, Furnish 3‐12" Led Vehicle Head, Install 3‐12" Led Vehicle Head, Furnish 4‐12" Led Vehicle Head, Install 4‐12" Led Vehicle Head, Furnish 5‐12" Led Vehicle Head, Install 5‐12" Led Vehicle Head, Furnish 3‐Section Pv Led Vehicle Head, Install 3‐Section Pv Led Vehicle Head, Furnish Driver Feedback Sign, Install Driver Feedback Sign, Astro Bracket‐Supply And Install, Furnish Led Pedestrian Head, Install Led Pedestrian Head, Furnish Led Countdown Pedestrian Head, Install Led Countdown Pedestrian Head, Furnish Rectangular Rapid Flashing Beacons, Install Rectangular Rapid Flashing Beacons, Furnish In Road Warning Lights, Install In Road Warning Lights, Furnish Led Blank‐Out Sign (No Right/Left Turn), Install Led Blank‐Out Sign (No Right/Left Turn), Handhole ‐ Hh‐1 (10.5"X 17"X 12") Sce, Handhole ‐ Hh‐2 (10.5"X 17"X 24") Sce, Handhole ‐ Hh‐3 (13"X 24"X 12") Sce, Handhole ‐ Hh‐4 (13"X 24"X 24") Sce, Handhole ‐ Hh‐5 (17"X 30"X 12") Sce, Handhole ‐ Hh‐6 (17"X 30"X 24") Sce, Handhole ‐ Hh‐7 (10.5"X 17"X 12") Sce, Handhole ‐ Hh‐8 (13"X 24"X 15") Sce, Handhole ‐ Hh‐9 (17"X 30"X 15") Sce, Handhole ‐ Hh‐10 (13"X 24"X 18") Sce, Handhole ‐ Hh‐11 (17"X 30"X 18") Sce, Handhole ‐ Hh‐12 (17"X 30"X 30") Sce, Handhole ‐ Hh‐13 (13" X 24" X 18"), Handhole ‐ Hh‐14 (17"X 30"X 18") Sce, Handhole ‐ Hh‐15 (17"X 30"X 30") Sce, Furnish Ppb ‐ Css W/Anchor Bolts, Install Ppb ‐ Css W/Anchor Bolts, Ppb ‐ Css W/Anchor Bolts Standard Foundation, Furnish Type 1A (10 Feet), Install Type 1A (10 Feet), Type 1A (10 Feet) Standard Foundation, Furnish Type 1B (16 Feet), Install Type 1B (16 Feet), Type 1D (14 Fe t) Standard, Furnish Type 15‐Fbs‐With Slip Base Plate And Bolts, Install Type 15‐Fbs‐With Slip Base Plate And olts, Type 15‐Fbs Standard Foundation, Furnish And Install Riser, Remove Streetlight Standard On Wood Pole, Furnish And Install 35' Class 5 Treated Douglas Fir Utility Pole, Furnish And Install 40' Class 5 Treated Douglas Fir Utility Pole, Furnish And Install 45' Class 5 Treated Douglas Fir Utility Pole, Furnish And Install 23'‐3" Concrete Type 1‐C1 Octagonal Pole, Furnish And Install 28'‐3" Concrete Type 1‐C1 Octagonal Pole, Furnish And Install 29'‐3" Concrete Type 1‐C1 Octagonal Pole, Price Adjustment For Traffic Signal Poles (Allowance Of $50,000)

Comet Electric, Inc is willing to break items of work into smaller increments to assist CBE Contractors and Suppliers in obtaining work on this project. 100% Performance and Payment bonds required. Subcontractor’s must possess a current contractor’s license.

Requirements: No Contractor or Subcontractor shall be qualified to bid on, be listed in a bid proposal or engage in the performance of any contract for public work, unless currently registered to perform public work with the Dept of Industrial Relations https://efiling.dir.ca.gov/PWCR/Search.action

Please call if you need any bidding assistance including but not limited to; obtaining bonding, insurance, equipment, materials and/or supplies. The US Small Business Administration may also assist you in obtaining bonding - please see the following site for information: http://www.sba.gov/content/contractors#
California Access to Capital Program Financing Solutions for your small business http://www.calbizfinance.org/cal_cert_biz_program.html

Comet Electric, Inc
21625 Prairie St, Chatsworth, CA 91311
Contact: Louis Perez
(818) 280-5754 Office
(818) 340-4033 Fax
louisperez@cometelectric.com

Published on January 6, 2021 @ 1:00 p.m. by Contractor’s Estimate, Inc.
Located at http://www.contractorsestimate.com

This advertisement will run until the bid date

 
NEWS
&
EVENTS

FEDERAL BIDDING OPPORTUNITIES

Caltrans Currently Advertised Projects

SAM SYSTEM FOR AWARD MANAGEMENT

SMBE/SWBE Query

Elite SDVOB Network

 

 
What are we about? Contact us HOME